Wire brief · Building and service wire

URD cable: direct burial, pad-mounts, subdivision laterals

URD is a utility description before it is a cable type. What the jacket print says underneath that description decides whether an inspector will accept the run.

CountyFranklin
RegionCentral Ohio
Typical lot2 AWG to 4/0 aluminium
InstallDirect burial, conduit ends

Request a quote

Tell the desk what you have in URD cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Lot details

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

A warehouse interior packed with cable reels, many wrapped in clear plastic.

A utility term, not a code article

URD stands for underground residential distribution, and it describes a job rather than a construction. What is sold under the name is a 600-volt single conductor, usually aluminium, insulated with cross-linked polyethylene or a high-molecular-weight polyethylene, with no overall jacket on the single-conductor forms. It is buried directly in the trench and rises into a pad-mount transformer or a meter pedestal at each end.

Multi-conductor URD exists too: triplex and quadruplex assemblies with two insulated conductors twisted around a bare neutral. Those are common on service laterals where the utility and the customer each own a side. The distinction worth holding on to is voltage. Secondary URD is a 600-volt product. Primary URD at 15 kV and above is shielded cable with a completely different handling story.

Dual rating: URD and USE-2 on the same jacket

Most of the cable sold to contractors is printed both URD and USE-2. The second marking is the one with a code standing. USE-2 is a recognised underground service entrance cable, rated 90°C in wet locations and marked for direct burial and sunlight resistance. URD on its own is a utility designation and does not, by itself, satisfy an inspector looking at a customer-owned lateral.

That matters in resale because the print is often the only thing separating two visually identical reels. A reel marked URD only may be perfectly good cable and still be the wrong reel for a contractor who needs a permitted installation. Photograph the print where the type letters fall, not just the size.

Pad-mounts, loops and the cable left at the transformer

Subdivision work leaves URD in the ground and on the reel. A crew pulls laterals to each lot, leaves a service loop coiled at the pedestal, and finishes with part-reels back on the truck. When a phase is redesigned, or a lot count drops, reels come back to the yard with most of their length on them.

The northern arc around Westerville and the growth corridors off I-270 have produced a steady amount of this. So has utility work: a transformer upgrade or a rebuild of a loop feed strands reels that were bought for the previous configuration. Those are the good lots, because the cable never went in the ground and the jacket is still slick.

Reels, dirt and what to declare

URD reels are heavy and they are usually wood. A 4/0 aluminium reel is not something to move with a pallet jack on gravel, and the lagging is often missing by the time it reaches a yard. Length is read from the tag and confirmed by counting wraps against the drum diameter.

  • Conductor size and metal for each reel
  • Whether the print carries USE-2 as well as URD
  • Insulation type as printed, XLPE or HMWPE
  • Tag footage and whether the reel is lagged
  • Whether the cable was in the ground and pulled back

Related pages

Adjacent cities, wire families and regional briefs.

Questions sellers ask

Is URD cable the same as USE-2?

Often it is the same reel, printed with both. USE-2 is the recognised underground service entrance rating for direct burial at 90°C wet. URD alone is a utility designation. If the print shows only URD, the reel is a utility lot rather than a permitted-installation lot.

Can 15 kV URD be handled like the 600-volt kind?

No. Primary URD is shielded medium voltage cable with a semiconducting layer and a metallic shield, and it needs the same care as any shielded cable: no tight bends, ends sealed, and a record of how it was stored. It is reviewed separately from secondary URD.

What if the reel tag is gone but the cable looks new?

Then the print carries the case. URD is printed along its length with the size, the insulation and the ratings, and a clean stretch of print is enough to identify a reel. Without either, the reel is unidentified aluminium conductor and is handled on metal content.

Request a quote

Tell the desk what you have in URD cable

Send the basics and a buyer reviews the lot, usually the same working day.

  • Reviewed by a buyer, not a scale
  • Reels, pallets, partials or a full truckload
  • Anywhere in Ohio, one desk
  1. 01Send the wire type, quantity and pickup city.
  2. 02A buyer reviews the lot and replies with a basis.
  3. 03Freight and release are agreed, then the load is booked.
614-715-3047

Second look at the lot

Everything helps, but the wire type, the quantity and the pickup city are enough to start.

No account, no upload. Photos can follow by text to 614-715-3047.

Call 614-715-3047 Request a quote